BX53MTRF-S |
BX53MRF-S |
BXFM |
||
|
Optical system |
UIS2 optical system (infinity-corrected) |
|||
|
Microscope frame |
Illumination |
Reflected/transmitted |
Reflected |
|
|
Focus |
Stroke: 25 mm |
Stroke: 30 mm |
||
|
Fine stroke per rotation: 100 μm |
Fine stroke per rotation: 200 μm |
|||
|
Minimum graduation: 1 μm |
Minimum graduation: 2 μm |
|||
|
With upper limit stopper, torque adjustment for coarse handle |
With torque adjustment for coarse handle |
|||
|
Max. specimen height |
35 mm (w/o spacer) |
65 mm (w/o spacer) |
Depends on the mounting configuration |
|
|
75 mm (with BX3M- ARMAD) |
105 mm (with BX3M- ARMAD) |
|||
|
Observation tube |
Wide-field FN 22 |
Inverted: binocular, trinocular, tilting binocular |
||
|
Erect: trinocular, tilting binocular |
||||
|
Super-wide-field FN 26.5 |
Inverted: trinocular |
|||
|
Erect: trinocular, tilting trinocular |
||||
|
Reflected light illumination |
Traditional observation technique |
BX3M-RLAS-S |
||
|
Coded, white LED, BF/DF/DIC/POL/MIX FS, AS (with centering mechanism) |
||||
|
BX3M-KMA-S |
||||
|
White LED, BF/DIC/POL/MIX FS, AS (with centering mechanism) |
||||
|
BX3M-RLA-S |
||||
|
100W halogen lamp, white LED, BF/DF/DIC/POL/MIX/ FS, AS (with centering mechanism), |
||||
|
BF/DF interlocking, ND filter |
||||
|
- |
U-KMAS |
|||
|
White LED, 100W halogen |
||||
|
Fiber illumination, BF/DIC/POL/MIX |
||||
|
Fluorescence |
BX3M-URAS-S |
|||
|
Coded, 100W mercury lamp, 4 position mirror unit turret, (standard: WB, WG, WU+BF etc) |
||||
|
With FS, AS (with centering mechanism), with shutter mechanism |
||||
|
Transmitted light |
White LED |
- |
||
|
Abbe/long working distance condensers |
||||
|
Revolving nosepiece |
For BF |
Sextuple, centering sextuple, septuple, coded quintuple (optional motorized revolving nosepieces) |
||
|
For BF/DF |
Sextuple, quintuple, centering quintuple, coded quintuple (optional motorized revolving nosepieces) |
|||
|
Stage |
Coaxial left (right) handle stage: |
- |
||
|
76 mm × 52 mm, with torque adjustment |
||||
|
Large-size coaxial left (right) handle stage: |
||||
|
105 mm × 100 mm, with locking mechanism in Y-axis |
||||
|
Large-size coaxial right handle stage: |
||||
|
150 mm × 100 mm, with torque adjustment and locking mechanism in Y-axis |
||||
|
Weight |
Approx. 18.3 kg |
Approx. 15.8 kg |
Approx. 11.1 kg |
|
|
(Microscope frame 7.6 kg) |
(Microscope frame 7.4 kg) |
(Microscope frame 1.9 kg) |
||
|
BX53MTRF-S |
BX53MRF-S |
BXFM |
||
|
Optical system |
UIS2 optical system (infinity-corrected) |
|||
|
Microscope frame |
Illumination |
Reflected/transmitted |
Reflected |
|
|
Focus |
Stroke: 25 mm |
Stroke: 30 mm |
||
|
Fine stroke per rotation: 100 μm |
Fine stroke per rotation: 200 μm |
|||
|
Minimum graduation: 1 μm |
Minimum graduation: 2 μm |
|||
|
With upper limit stopper, torque adjustment for coarse handle |
With torque adjustment for coarse handle |
|||
|
Max. specimen height |
35 mm (w/o spacer) |
65 mm (w/o spacer) |
Depends on the mounting configuration |
|
|
75 mm (with BX3M-ARMAD) |
105 mm (with BX3M-ARMAD) |
|||
|
Observation tube |
Wide-field FN 22 |
Inverted: binocular, trinocular, tilting binocular |
||
|
Erect: trinocular, tilting binocular |
||||
|
Super-wide-field FN 26.5 |
Inverted: trinocular |
|||
|
Erect: trinocular, tilting trinocular |
||||
|
Reflected light illumination |
Traditional observation technique |
BX3M-RLAS-S |
||
|
Coded, white LED, BF/DF/DIC/POL/MIX FS, AS (with centering mechanism) |
||||
|
BX3M-KMA-S |
||||
|
White LED, BF/DIC/POL/MIX FS, AS (with centering mechanism) |
||||
|
BX3M-RLA-S |
||||
|
100W halogen lamp, white LED, BF/DF/DIC/POL/MIX/ FS, AS (with centering mechanism), |
||||
|
BF/DF interlocking, ND filter |
||||
|
- |
U-KMAS |
|||
|
White LED, 100W halogen |
||||
|
Fiber illumination, BF/DIC/POL/MIX |
||||
|
Fluorescence |
BX3M-URAS-S |
|||
|
Coded, 100W mercury lamp, 4 position mirror unit turret, (standard: WB, WG, WU+BF etc) |
||||
|
With FS, AS (with centering mechanism), with shutter mechanism |
||||
|
Transmitted light |
White LED |
- |
||
|
Abbe/long working distance condensers |
||||
|
Revolving nosepiece |
For BF |
Sextuple, centering sextuple, septuple, coded quintuple (optional motorized revolving nosepieces) |
||
|
For BF/DF |
Sextuple, quintuple, centering quintuple, coded quintuple (optional motorized revolving nosepieces) |
|||
|
Stage |
Coaxial left (right) handle stage: |
- |
||
|
76 mm × 52 mm, with torque adjustment |
||||
|
Large-size coaxial left (right) handle stage: |
||||
|
105 mm × 100 mm, with locking mechanism in Y-axis |
||||
|
Large-size coaxial right handle stage: |
||||
|
150 mm × 100 mm, with torque adjustment and locking mechanism in Y-axis |
||||
|
Weight |
Approx. 18.3 kg |
Approx. 15.8 kg |
Approx. 11.1 kg |
|
|
(Microscope frame 7.6 kg) |
(Microscope frame 7.4 kg) |